This page provides a few examples of Absopulse's generic designs.

We can accommodate almost any input/output configuration requirement.

Our engineering team would be pleased to present a cost-effective solution for your exact specifications.

Encapsulated Designs
DC/DC - RWY (Railway) Series for Railway Applications
Encapsulated to ensure immunity to shock, vibration, moisture, humidity, dust and insects.
1Model
Standard input ranges (Vdc):

24V (14.4
- 37Vdc)
36V (22 - 55Vdc)
48V (28 - 74Vdc)
72V (42 - 110Vdc)
110V (57-168Vdc)
No. of outputs
Maximum Output Power

Package Type Features
RWF 15..30 24, 36,48, 72, 96,110 1 30 P100: 58 x 61 x 180 mm
2.3" x 2.4" x 7.1"
Video Monitoring, Wireless Networks. Encapsulated.
Railway & harsh-environments.
RWY 30..100 24, 36,48, 72, 96,110 1 100 P100: 58 x 61 x 180 mm
2.3" x 2.4" x 7.1"
Encapsulated.
Railway & harsh-environments.
RWY 50-72/48 72 1 150 P100: 58 x 61 x 180 mm
2.3" x 2.4" x 7.1"
Encapsulated.
Railway & harsh-environments.
RWY 150  24, 36,48, 72,110 1 150 P100: 58 x 61 x 180 mm
2.3" x 2.4" x 7.1"
Encapsulated.
Railway & harsh-environments.
RWY 72 48, 72,110  2 150 P300: 113 x 53 x 201 mm
4.4" x 2.1" x 7.9"
Encapsulated.
Railway & harsh-environments.
RWY 200  24, 36,48, 72, 96,110 1 200 P200: 69 x 58 x 211 mm
2.7" x 2.3" x 8.3"
Encapsulated.
Railway & harsh-environments.
RWD 200 24, 36,48, 72,110 1 200 P200: 69 x 58 x 211 mm
2.7" x 2.3" x 8.3"
Redundant operation. Encapsulated.
Railway & harsh-environments.
RWY 182 24, 36,48, 72,110  2 200 P100: 113 x 53 x 201 mm
4.4" x 2.1" x 7.9"
Encapsulated.
Railway & harsh-environments.
RWY 272 36,48, 72,110  2 200 P100: 113 x 53 x 201 mm
4.4" x 2.1" x 7.9"
Encapsulated.
Railway & harsh-environments.
RWY 250 36,48, 72,110  2 250 P100: 113 x 53 x 201 mm
4.4" x 2.1" x 7.9"
Encapsulated.
Railway & harsh-environments.
RWY 280 36,48, 72,110 1 280 P100: 113 x 53 x 201 mm
4.4" x 2.1" x 7.9"
Encapsulated.
Railway & harsh-environments.
RWY 282  36,48, 72,110  2 280 P100: 113 x 53 x 201 mm
4.4" x 2.1" x 7.9"
Encapsulated.
Railway & harsh-environments.
Return to top
DC/DC - PDC Series: Industrial & other Heavy-Duty Applications
Encapsulated to ensure immunity to shock, vibration, moisture, humidity, dust and insects.
PDC 250 125 (105 - 140)

250 (210 - 280)
1 250 P59: 108 x 51 x 191 mm
4.3" x 2.8" x 7.5"
Encapsulated for harsh-environments
PDC 400 24, 36, 48, 125 1 400 P400: 131 x 76 x 232 mm
5.2" x 3" x 9.1"
Encapsulated for harsh-environments
Return to top
DC/DC - DIO 122 Series: Industrial & other Heavy-Duty Applications
Encapsulated, 20kV Isolation Voltage, (Corona free) DC-DC Converters
DIO 122 48 (44 - 56) 2 120 4" x12" x 2.75" 20kV isolation input/output and output/output - corona free at 12kV
Return to top
AC/DC - PWI & POL Series: Industrial & other Heavy-Duty Applications -
Encapsulated for immuity to shock, vibration, moisture, humidity, dust and insects.
Generic Model Standard Input Voltage Range: No. of outputs Maximum Output Power Package Type FeaturesFeatures
PWI 100 universal 1 100 P99: 81 x 71 x 156 mm
3.2" x 2.8" x 6.2"
Encapsulated for harsh-environments
POL 59 115/230 1 250 P59: 108 x 51 x 191 mm
4.3" x 2.8" x 7.5"
Encapsulated for harsh-environments
POL 400 115/230 1 400 P400: 131 x 76 x 232 mm
5.2" x 3" x 9.1"
Encapsulated for harsh-environments
POL 319 115/230 1 500 152 x 79 x 353 mm
6" x 3.1"x13.9"
Encapsulated for harsh-environments
Return to top
AC/DC - PPF Series (Power Factor Corrected-Input)
Encapsulated for immuity to shock, vibration, moisture, humidity, dust and insects.
PPF 300 universal 1 300 P300:113 x53x201 mm
4.4" x 2.1" x 7.9"
Encapsulated for harsh-environments
PPF 65 universal 1 500 P 65: 155x68x279 mm
6.1" x 2.7" x 11"
Encapsulated for harsh-environments
Return to top
Heavily Ruggedized Designs
DC/DC - BAP Railway Series
Model Standard input ranges (Vdc):

24V (17
- 30Vdc)
36V (25 - 45Vdc)
72V (50 - 90Vdc)
110V (77-137Vdc)
No. of outputs Maximum Output Power Package Type Features
BAP 236R-EH 24,36,48,72,96,110 1 200 3Ux14HPx220mm Plug-in (Eurocard) for 19" applications.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
BAP 236R 24,36,48,72,96,110 1 200 F2: 4.43" x 2.25" x 10"
112.5 x 57.2 x 254.0 mm
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
BAP 65R 36, 72, 96, 110 1 300 F3: 5.2" x 2.46" x 11.4"
132.1 x 62.5 x 289.6mm
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
BAR 65 72, 96, 110 1 300 F3: 5.2" x 2.46" x 11.4"
132.1 x 62.5 x 289.6mm
Built-in RIA 12 protection.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
BAP 319R 36, 72, 96, 110 1 500 F4: 5.1x 2.63" x13.82
129.5 x 66.8 x 351.0 mm
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
Return to top
DC/DC Converter with 5 Individually Fused Output terminals for Mobile and other Heavy-duty Applications
BAP 65-5FD-24/12FT 24 1 300 F3: 132 x 62 x 290 mm 5.2" x 2.5" x 11.4" 5 individually fused output terminals for mobile and other demanding applications
Return to top
DC/DC - DCW Railway Series
Wide Input Ranges
Model Standard input range: any one voltage +/-15% between 24VDC..125VDC Exceptions indicated below No. of outputs
Maximum Output Power
Package Type
Features
DCW 100R 48, 72, 96, 110
1
100
F0: 3.4"x1.9"x 6.10"
86.4 x 48.3 x 154.9 mm
Wide DC-input range.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
DCW 102R 48, 72, 96, 110
2
100
F0: 3.4" x 1.9" x 6.10"
86.4 x 48.3 x 154.9 mm
Wide DC-input range.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.

DCW 100R-EH

48, 72, 96, 110
1
100
3Ux10HPx160 mm
Plug-in (Eurocard) - 19" applications.
Wide DC-input range.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
DCW 150R 48, 72, 96, 110
1
150
F1: 4.4" x 2" x 7.8"
113 x 50.8 x 198.1 mm
Wide DC-input range.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
DCW 152R 48, 72, 96, 110
2
150
F1: 4.4" x 2" x 7.8"
113 x 50.8 x 198.1 mm
Wide DC-input range.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
Return to top
DC/DC - HVI Series
High Input Voltage Converters
1Model Input range No. of outputs Maximum Output Power Package Type Features
HVI 109 WR-XT 600 nominal 400..800 range 1 100 F2: 4.43" x 2.25" x 10"
112.5 x 57.2 x 254.0 mm
High DC input. Wide input range.
Heavy ruggedizing & conformal coating for harsh-environments
HVI 2K-750/24 750
525 - 975 range
1 2000 5.5" x 7.5" x 15"
139.7 x 190.5 x 381 mm
High DC input. Heavy ruggedizing & conformal coating for harsh-environments
Return to top
NOTE:
12VDC input versions of most of the above listed converters are available with derating. Please consult factory.

Copyright ©2005 Absopulse Electronics Ltd. All Rights Reserved