| Encapsulated Designs |
DC/DC - RWY (Railway) Series for Railway Applications
Encapsulated to ensure immunity to shock, vibration, moisture, humidity, dust and insects. |
| 1Model |
Standard input ranges (Vdc):
24V (14.4 - 37Vdc)
36V (22 - 55Vdc)
48V (28 - 74Vdc)
72V (42 - 110Vdc)
110V (57-168Vdc)
|
No. of outputs |
|
Package Type |
Features |
| RWF 15..30 |
24, 36,48, 72, 96,110 |
1 |
30 |
P100: 58 x 61 x 180 mm
2.3" x 2.4" x 7.1" |
Video Monitoring, Wireless Networks. Encapsulated.
Railway & harsh-environments. |
| RWY 30..100 |
24, 36,48, 72, 96,110 |
1 |
100 |
P100: 58 x 61 x 180 mm
2.3" x 2.4" x 7.1" |
Encapsulated.
Railway & harsh-environments. |
| RWY 50-72/48 |
72 |
1 |
150 |
P100: 58 x 61 x 180 mm
2.3" x 2.4" x 7.1" |
Encapsulated.
Railway & harsh-environments. |
| RWY 150 |
24, 36,48, 72,110 |
1 |
150 |
P100: 58 x 61 x 180 mm
2.3" x 2.4" x 7.1" |
Encapsulated.
Railway & harsh-environments. |
| RWY 72 |
48, 72,110 |
2 |
150 |
P300: 113 x 53 x 201 mm
4.4" x 2.1" x 7.9" |
Encapsulated.
Railway & harsh-environments. |
| RWY 200 |
24, 36,48, 72, 96,110 |
1 |
200 |
P200: 69 x 58 x 211 mm
2.7" x 2.3" x 8.3" |
Encapsulated.
Railway & harsh-environments. |
| RWD 200 |
24, 36,48, 72,110 |
1 |
200 |
P200: 69 x 58 x 211 mm
2.7" x 2.3" x 8.3" |
Redundant operation. Encapsulated.
Railway & harsh-environments. |
| RWY 182 |
24, 36,48, 72,110 |
2 |
200 |
P100: 113 x 53 x 201 mm
4.4" x 2.1" x 7.9" |
Encapsulated.
Railway & harsh-environments. |
| RWY 272 |
36,48, 72,110 |
2 |
200 |
P100: 113 x 53 x 201 mm
4.4" x 2.1" x 7.9" |
Encapsulated.
Railway & harsh-environments. |
| RWY 250 |
36,48, 72,110 |
2 |
250 |
P100: 113 x 53 x 201 mm
4.4" x 2.1" x 7.9" |
Encapsulated.
Railway & harsh-environments. |
| RWY 280 |
36,48, 72,110 |
1 |
280 |
P100: 113 x 53 x 201 mm
4.4" x 2.1" x 7.9" |
Encapsulated.
Railway & harsh-environments. |
| RWY 282 |
36,48, 72,110 |
2 |
280 |
P100: 113 x 53 x 201 mm
4.4" x 2.1" x 7.9" |
Encapsulated.
Railway & harsh-environments. |
| Return to top |
DC/DC - PDC Series: Industrial & other Heavy-Duty Applications
Encapsulated to ensure immunity to shock, vibration, moisture, humidity, dust and insects. |
| PDC 250 |
125 (105 - 140)
250 (210 - 280) |
1 |
250 |
P59: 108 x 51 x 191 mm
4.3" x 2.8" x 7.5" |
Encapsulated for harsh-environments |
| PDC 400 |
24, 36, 48, 125 |
1 |
400 |
P400: 131 x 76 x 232 mm
5.2" x 3" x 9.1" |
Encapsulated for harsh-environments |
| Return to top |
DC/DC - DIO 122 Series: Industrial & other Heavy-Duty Applications
Encapsulated, 20kV Isolation Voltage, (Corona free) DC-DC Converters |
| DIO 122 |
48 (44 - 56) |
2 |
120 |
4" x12" x 2.75" |
20kV isolation input/output and output/output - corona free at 12kV |
| Return to top |
AC/DC - PWI & POL Series: Industrial & other Heavy-Duty Applications -
Encapsulated for immuity to shock, vibration, moisture, humidity, dust and insects. |
| Generic Model |
Standard Input Voltage Range: |
No. of outputs |
Maximum Output Power |
Package Type |
FeaturesFeatures |
| PWI 100 |
universal |
1 |
100 |
P99: 81 x 71 x 156 mm
3.2" x 2.8" x 6.2" |
Encapsulated for harsh-environments |
| POL 59 |
115/230 |
1 |
250 |
P59: 108 x 51 x 191 mm
4.3" x 2.8" x 7.5" |
Encapsulated for harsh-environments |
| POL 400 |
115/230 |
1 |
400 |
P400: 131 x 76 x 232 mm
5.2" x 3" x 9.1" |
Encapsulated for harsh-environments |
| POL 319 |
115/230 |
1 |
500 |
152 x 79 x 353 mm
6" x 3.1"x13.9"
|
Encapsulated for harsh-environments |
| Return to top |
AC/DC - PPF Series (Power Factor Corrected-Input)
Encapsulated for immuity to shock, vibration, moisture, humidity, dust and insects. |
| PPF 300 |
universal |
1 |
300 |
P300:113 x53x201 mm
4.4" x 2.1" x 7.9" |
Encapsulated for harsh-environments |
| PPF 65 |
universal |
1 |
500 |
P 65: 155x68x279 mm
6.1" x 2.7" x 11" |
Encapsulated for harsh-environments |
| Return to top |
| Heavily Ruggedized Designs |
| DC/DC - BAP Railway Series |
| Model |
Standard input ranges (Vdc):
24V (17 - 30Vdc)
36V (25 - 45Vdc)
72V (50 - 90Vdc)
110V (77-137Vdc)
|
No. of outputs |
Maximum Output Power |
Package Type |
Features |
| BAP 236R-EH |
24,36,48,72,96,110 |
1 |
200 |
3Ux14HPx220mm |
Plug-in (Eurocard) for 19" applications.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments. |
| BAP 236R |
24,36,48,72,96,110 |
1 |
200 |
F2: 4.43" x 2.25" x 10"
112.5 x 57.2 x 254.0 mm |
Heavy ruggedizing & conformal coating.
Railway & harsh-environments. |
| BAP 65R |
36, 72, 96, 110 |
1 |
300 |
F3: 5.2" x 2.46" x 11.4"
132.1 x 62.5 x 289.6mm |
Heavy ruggedizing & conformal coating.
Railway & harsh-environments. |
| BAR 65 |
72, 96, 110 |
1 |
300 |
F3: 5.2" x 2.46" x 11.4"
132.1 x 62.5 x 289.6mm |
Built-in RIA 12 protection.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments. |
| BAP 319R |
36, 72, 96, 110 |
1 |
500 |
F4: 5.1x 2.63" x13.82
129.5 x 66.8 x 351.0 mm |
Heavy ruggedizing & conformal coating.
Railway & harsh-environments. |
Return to top
|
| DC/DC Converter with 5 Individually Fused Output terminals for Mobile and other Heavy-duty Applications |
| BAP 65-5FD-24/12FT |
24 |
1 |
300 |
F3: 132 x 62 x 290 mm 5.2" x 2.5" x 11.4" |
5 individually fused output terminals for mobile and other demanding applications |
Return to top
|
DC/DC - DCW Railway Series
Wide Input Ranges |
| Model |
Standard input range: any one voltage +/-15% between 24VDC..125VDC Exceptions indicated below |
No. of outputs |
Maximum Output Power
|
Package Type |
Features
|
| DCW 100R |
48, 72, 96, 110 |
1
|
100
|
F0: 3.4"x1.9"x 6.10"
86.4 x 48.3 x 154.9 mm
|
Wide DC-input range.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
|
| DCW 102R |
48, 72, 96, 110 |
2
|
100
|
F0: 3.4" x 1.9" x 6.10"
86.4 x 48.3 x 154.9 mm
|
Wide DC-input range.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
|
DCW 100R-EH
|
48, 72, 96, 110 |
1
|
100
|
3Ux10HPx160 mm
|
Plug-in (Eurocard) - 19" applications.
Wide DC-input range.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
|
| DCW 150R |
48, 72, 96, 110 |
1
|
150
|
F1: 4.4" x 2" x 7.8"
113 x 50.8 x 198.1 mm
|
Wide DC-input range.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
|
| DCW 152R |
48, 72, 96, 110 |
2
|
150
|
F1: 4.4" x 2" x 7.8"
113 x 50.8 x 198.1 mm
|
Wide DC-input range.
Heavy ruggedizing & conformal coating.
Railway & harsh-environments.
|
Return to top
|
DC/DC - HVI Series
High Input Voltage Converters
|
| 1Model |
Input range |
No. of outputs |
Maximum Output Power |
Package Type |
Features |
| HVI 109 WR-XT |
600 nominal 400..800 range |
1 |
100 |
F2: 4.43" x 2.25" x 10"
112.5 x 57.2 x 254.0 mm |
High DC input. Wide input range.
Heavy ruggedizing & conformal coating for harsh-environments |
| HVI 2K-750/24 |
750
525 - 975 range |
1 |
2000 |
5.5" x 7.5" x 15"
139.7 x 190.5 x 381 mm |
High DC input. Heavy ruggedizing & conformal coating for harsh-environments |
Return to top
|