The stand-alone AC/DC power supplies listed on this page are housed in enclosed packages. For modular power systems and plug-in (Eurocard) modules, please refer to the Power Systems section.

This page provides a few examples of Absopulse's generic AC-DC Power Supply and Battery Charger designs. Our engineering team would be pleased to present a cost-effective solution for your design requirements.



Encapsulated (Potted) Series -
for immuity to shock, vibration, moisture, humidity, dust and insects.
Generic Model Standard Input Voltage Range: 115/230 +/-15% No. of outputs MAXIMUM output parameters - VA can not exceed maximum output power Package Type Features
Power (Watts) Voltage (Volts) Current (Amps)
PWI 100 universal 1 100 48 8 P99: 81 x 71 x 156 mm
3.2" x 2.8" x 6.2"
Adverse environment applications
POL 59 115/230 1 250 48 20 P59: 108 x 51 x 191 mm
4.3" x 2.8" x 7.5"
Encapsulated for harsh-environments
POL 400 115/230 1 400 48 33 P400:131 x 76 x 232 mm
5.2" x 3" x 9.1"
Encapsulated for harsh-environments
POL 319 115/230 1 500 48 40 152 x 79 x 353 mm
6" x 3.1"x13.9"
Encapsulated for harsh-environments
Return to top
HVC Series
High Output Voltage Converters
Generic Model Standard Input Voltage Range: 115/230 +/-15% No. of outputs MAXIMUM output parameters - VA can notexceed maximum output power Package Type Features
Power (Watts) Voltage (Volts) Current (Amps)
HVC 319 115/230 1 500 240 6 F4:129 x 67 x 351 mm
5.1x 2.6" x 13.8"
High output voltage
HVC 319F 115/230 1 700 250 5.6 FF4:151x62x356mm
6"x 2.43"x 14.03"
High voltage
HVC 2K 230 1 3000 300 23 11.5" x5.3"x16.25" High voltage
Return to top
Standard AC-DC Power Supplies
Generic Model
Standard Input Voltage Range: 115/230 +/-15%
No. of outputs
MAXIMUM output parameters - VA can not exceed maximum output power
Package Type Features
Power (Watts) Voltage (Volts) Current (Amps)
HRW 40 universal 1 40 24 3 3"x3" (1.5" component hght) High Reliability, open frame
EOL 70 115/230 1 60 48 5 F1: 113 x 51 x 198 mm
4.4" x 2" x 7.8"
Available as Eurocard
(plug-in module)
EOL 76 115/230 3 60 5,+/-12 6 F1: 113 x 51 x 198 mm
4.4" x 2" x 7.8"
Available as Eurocard
(plug-in module)
SIM 98 universal 4 65 5,+/-12,24 5 6.25"x4.1"x1.5" Open Frame
HOW 100 universal 1 100 130 20 F0: 86 x 48 x 155 mm
3.4" x 1.9" x 6.1"
Medical grade
EOW 70 universal 1 100 60 12 F0: 86 x 48 x 155 mm
3.4" x 1.9" x 6.1"
-
MIW 100 universal 1 100 130 8 F0: 86 x 48 x 155 mm
3.4" x 1.9" x 6.1"
-
MIW 102 universal 2 100 130,130 6,6 F0: 86 x 48 x 155 mm
3.4" x 1.9" x 6.1"
Universal
LIN 67 115/230 3 100 24,+/-24 10, +/-1 F2:113 x 57 x 254 mm
4.4" x 2.3" x 10"
 -
MIW 103 Universal 3 100 130 6,1,3,1 F1: 113 x 51 x 198 mm
4.4" x 2" x 7.8"
Universal
MIW 104 universal 4 100 130 6,1,3,1 F1: 113 x 51 x 198 mm
4.4" x 2" x 7.8"
Universal
MIW 150 universal 1 150 130 12 F1: 113 x 51 x 198 mm
4.4" x 2" x 7.8"
Universal
MIW 152 universal 2 150 130,130 12,12 F1: 113 x 51 x 198 mm
4.4" x 2" x 7.8"
Universal
MIW 162 universal 2 150
+/-12,
+/-24, +/-48
6,3,1.5 F1: 113 x 51 x 198 mm
4.4" x 2" x 7.8"
-
EOL 67 115/230 3 150 5,+/-12 12, +/-3 F2:113 x 57 x 254 mm
4.4" x 2.3" x 10"
 -
OPF 84 115/230 5 150 24 15,+/-3,-1 F3:132 x 62 x 290 mm
5.2" x 2.5" x 11.4"
 -
EOL 59 115/230 1 180 60 20 F1: 113 x 51 x 198 mm
4.4" x 2" x 7.8"
 -
EOL 90 115/230 1 180 60 15 F2:113 x 57 x 254 mm
4.4" x 2.3" x 10"
 -
EOL 95 115/230 2 180 60,60 6,6 F2:113 x 57 x 254 mm
4.4" x 2.3" x 10"
- 
OLC 53 115/230 1 200 120 25 F2:113 x 57 x 254 mm
4.4" x 2.3" x 10"
 -
HBC 200 115/230 1 200 125 16 F2:113 x 57 x 254 mm
4.4" x 2.3" x 10"
Rugged, cost-optimized Industrial
HBC 65 115/230 1 300 125 25 F3:132 x 62 x 290 mm
5.2" x 2.5" x 11.4"
Conduction/convection cooled
HBC 265 115/230 2 300 120,120 15,15 F3:132 x 62 x 290 mm
5.2" x 2.5" x 11.4"
 -
HBC 465 115/230 4 300 24,+/-24,-24 20,+/-3,-1 F3:132 x 62 x 290 mm
5.2" x 2.5" x 11.4"
 -
MIW 302 universal 2 300 125 15 F3:132 x 62 x 290 mm
5.2" x 2.5" x 11.4"
Both outputs highly regulated and individually adjustable
HBC 65F 115/230 1 500 125 40 FF3:153 x61x295 mm
6" x 2.4" x 11.62
Forced air
HBC 319 115/230 1 500 125 20 F4:129 x 67 x 351 mm
5.1x 2.6" x 13.8"
Convection/conduction cooled
LVC 319 115/230 1 500 20 40 F4:129 x 67 x 351 mm
5.1x 2.6" x 13.8"
Low DC output
HBC 319F 115/230 1 700 125 29 FF4:151x62x356mm
6"x 2.43"x 14.03"
Forced air
HBL 1K 115/230 1 1000 56 38 F6:210x66x351 mm
8.3" x 2.6" x 13.8"
Rugged, Industrial conduction/convecgtion cooled
HBC 1000 115/230 1 1000 60 75 UT Forced air
2HBC 265 115/230 4 1000 - - 17.4"X4.9"X11.5" -
HBC 1200 115/230 1 1200 60 50 UT Forced air
HBL 1K5F 230 1 1500 125 62 FF6:236x66x340 mm 9.3" x 2.6" x 13.8" Forced air
MOT 2000 170...265 1 2000 54 70 7.4"x4.9"x11.5" Forced air
HBL 2KF 230 1 2000 125 83 FF6:236x66x340 mm 9.3" x 2.6" x 13.8" Forced air
HBC 5000 180...264 1 5000 300 25 4Ux19"x15" 19" rack mount
Note: Most models can be equipped with auto-ranging or switch selection 115/230 as an option.
Return to top
Encapsulated PFC-Input (Power Factor Corrected) Power Supplies
for immuity to shock, vibration, moisture, humidity, dust and insects.
PPF 300 universal 1 300 72 25 P300:113 x53x201 mm
4.4" x 2.1" x 7.9"
Encapsulated for harsh-environments
PPF 65 universal 1 500 72 30 P 65: 155x68x279 mm
6.1" x 2.7" x 11"
Encapsulated for harsh-environments
Return to top
PFC (Power Factor Corrected) Power Supplies
PFC 67 universal 3 100 24,+/-24 10,+/-3 F2:113 x 57 x 254 mm
4.4" x 2.3" x 10"
 -
PFC 90 universal 1 150 60 20 F2:113 x 57 x 254 mm
4.4" x 2.3" x 10"
 -
PFC 53 universal 1 200 120 25 F2:113 x 57 x 254 mm
4.4" x 2.3" x 10"
 -
PFC 65 universal 1 300 125 25 F3:132 x 62 x 290 mm
5.2" x 2.5" x 11.4"
-
PFC 319 universal 1 450 60 20 F4:129 x 67 x 351 mm 5.1x 2.6" x 13.8"
PFC 622 universal 1 500 48 20 6U x 16HP x 220 mm Plug-in (Eurocard Module)
PFC 65F universal 1 500 48 40 FF3:153 x61x295 mm 6" x 2.4" x 11.62 Forced air
PFC 700 universal 1 700 13.2 60 8.2" x 2.2" x 10" Low profile
PFC 319F universal 1 750 125 31 FF4:151x62x356 mm
6"x 2.43"x 14.03"
Forced air
PFL 800 universal 1 800 48 33 1.75" x 19" x 20" Low profile
PFC 1000 universal 1 1000 120 40/75 F5 Forced air
PFC 1500 universal 1 1500 125 120 F5 Forced air
PFL 1500F universal 1 1500 125 62 F20: 279x64x 292 mm
11" x 2.5" x 11.5"
Low profile,
Forced air
PFC 4500 universal 1 4500 48 31 34"x19"x28" High power
PFC 6000 universal 1 6000 54 500 4U x 19" x 25" High power
PFC 6300 universal 2 6300 48 500 34"x19"x28" High power
Return to top

Battery Chargers/UPS
BCH 150
formerly BCH 1663
95-264ac
or
120-360dc
1 150 24 86 F2:113 x 57 x 254 mm
4.4" x 2.3" x 10"
LBD, Alarms
BCH 151 95-264ac
or
120-360dc
1 150 55.2 10.86 F2:113 x 57 x 254 mm
4.4" x 2.3" x 10"
LBD, BTC, Charger Fail Alarm, LBA
BCM 150 95-264ac
or
120-360dc
1 150 55.2 10.86 F2:113 x 57 x 254 mm
4.4" x 2.3" x 10"
A-Meter,
Alarms (optional)
BCH 300 115/230 1 300 125 - F3:132 x 62 x 290 mm
5.2" x 2.5" x 11.4"
Charger Fail Alarm
BCH 301 & BCP 301 (PFC-input) 115/230

90-264 PFC
1 300 125 18 F4:129 x 67 x 351 mm
5.1x 2.6" x 13.8"
LBD, BTC (option), C-Fail Alarm, LBA
PFC&non-PFC-Input
BCP 300 - 500T 115/230
or 250Vdc
1 300-500 400 - 429 x 244 x 341 mm
16.93" x 9.61" x 13.42"
Transportable. Heavy ruggedizing, conformal coating, waterproof case
BCH MO1 115/230 1 300-750 138 - 4U (6.97")x19"x7" Configurable charger system
BCH 500 115/230 1 500 24,48 18A F4:129 x 67 x 351 mm
5.1x 2.6" x 13.8"
Charger fail alarm
BCH 501 & BCP 501
(PFC-input)
115/230

90-264 PFC
1 500 125 22 F5 for 24V
Special for 48V and 125V
LBD, BTC (option), C-Fail Alarm, LBA
PFC&non-PFC-Input
Abbreviations: LBD: Low Battery Disconnect; BTC: Battery Temperature Compensation; LBA: Low Battery Alarm
Return to top

DC- Output Mini-UPS Systems (stand-alone)
UPS 12-7AH 95 ... 264 1 50 13.6 3 6.2"x2.8"x10" Built-in 7AH battery. Compact design.
UPS 12-14AH 95 ... 264 1 150 13.8 10 5.5" x 7"x 10"
Built-in 14AH battery. Compact.
Return to top


Medical Power Supplies (UL 601.1)
HOW 100 95 - 264 1 100 130 20 3.4 "x 6.1"x1.9" -
MPS 520 115/230 6 180 12 20 AT style Autoranging
Return to top


AC - Fail Alarm Circuit