The stand-alone AC/DC power supplies listed on this page are housed in enclosed packages. For modular power systems and plug-in (Eurocard) modules, please refer to the Power Systems section.

This page provides a few examples of Absopulse's generic AC-DC Power Supply and Battery Charger designs. Our engineering team would be pleased to present a cost-effective solution for your design requirements.



Encapsulated (Potted) Series -
for immuity to shock, vibration, moisture, humidity, dust and insects.
Generic Model Standard Input Voltage Range: 115/230 +/-15% No. of outputs MAXIMUM output parameters - VA can not exceed maximum output power Package Type Features
Power (Watts) Voltage (Volts) Current (Amps)
PWI 100 universal 1 100 48 8A P99: 81.3 x 71.1 x 156.2 mm
3.2" x 2.8" x 6.15"
Encapsulated for harsh-environments
POL 59 115/230 1 250 48 20A P59: 108 x 70 x 191 mm
4.25" x 2.75" x 7.5"
Encapsulated for harsh-environments
POL 400 115/230 1 400 48 33A P400: 130.8 x 76.2 x 231.9 mm
5.15" x 3" x 9.13"
Encapsulated for harsh-environments
POL 319 115/230 1 500 48 40A 152 x 79 x 353 mm
6" x 3.1" x 13.9"
Encapsulated for harsh-environments
Return to top
HVC Series
High Output Voltage Converters
Generic Model Standard Input Voltage Range: 115/230 +/-15% No. of outputs MAXIMUM output parameters - VA can notexceed maximum output power Package Type Features
Power (Watts) Voltage (Volts) Current (Amps)
HVC 319 115/230 1 500 240 6A F4:130 x 62 x 353 mm
5.1" x 2.43" x 13.9
High output voltage
HVC 319F 115/230 1 700 250 5.6A FF4: 155 x 62 x 356 mm
6.1"x 2.43"x 14"
High voltage
HVC 2K 230 1 3000 300 23A I 5: 292.1x135.9x 412.8 mm
11.5" x 5.35" x 16.25"
High voltage
Return to top
Standard AC-DC Power Supplies
Generic Model
Standard Input Voltage Range: 115/230 +/-15%
No. of outputs
MAXIMUM output parameters - VA can not exceed maximum output power
Package Type Features
Power (Watts) Voltage (Volts) Current (Amps)
HRW 40 universal 1 40 24 3A 3"x3" (1.5" component hght) High Reliability, open frame
EOL 70 115/230 1 60 48 5A F1: 112.5 x 50.8 x 201 mm
4.43" x 2" x 7.91"
Available as Eurocard
(plug-in module)
EOL 76 115/230 3 60 5,+/-12 6A F1: 112.5 x 50.8 x 201 mm
4.43" x 2" x 7.91"
Available as Eurocard
(plug-in module)
SIM 98 universal 4 65 5,+/-12,24 5A 158.7 x 104.1 x 38.1 mm
6.25" x 4.1" x 1.5"
Open Frame
HOW 100 universal 1 100 130 20A F0: 86.4 x 48.3 x 154.9 mm
3.4" x 1.9" x 6.10"
Medical grade
EOW 70 universal 1 100 60 12A F0: 86.4 x 48.3 x 154.9 mm
3.4" x 1.9" x 6.10"
-
MIW 100 universal 1 100 130 8A F0: 86.4 x 48.3 x 154.9 mm
3.4" x 1.9" x 6.10"
-
MIW 102 universal 2 100 130,130 6,6A F0: 86.4 x 48.3 x 154.9 mm
3.4" x 1.9" x 6.10"
Universal
LIN 67 115/230 3 100 24,+/-24 10, +/-1A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
 -
MIW 103 Universal 3 100 130 6,1,3,1A F1: 112.5 x 50.8 x 201 mm
4.43" x 2" x 7.91"
Universal
MIW 104 universal 4 100 130 6,1,3,1A F1: 112.5 x 50.8 x 201 mm
4.43" x 2" x 7.91"
Universal
MIW 150 universal 1 150 130 12A F1: 112.5 x 50.8 x 201 mm
4.43" x 2" x 7.91"
Universal
MIW 152 universal 2 150 130,130 12,12A F1: 112.5 x 50.8 x 201 mm
4.43" x 2" x 7.91"
Universal
MIW 162 universal 2 150
+/-12,
+/-24, +/-48
6,3,1.5A F1: 112.5 x 50.8 x 201 mm
4.43" x 2" x 7.91"
-
EOL 67 115/230 3 150 5,+/-12 12, +/-3A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
 -
OPF 84 115/230 5 150 24 15,+/-3,-1A F3: 132 x 62 x 300 mm
5.2" x 2.4" x 11.8"
 -
EOL 59 115/230 1 180 60 20A F1: 112.5 x 50.8 x 201 mm
4.43" x 2" x 7.91"
 -
EOL 90 115/230 1 180 60 15A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
 -
EOL 95 115/230 2 180 60,60 6,6A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
- 
OLC 53 115/230 1 200 120 25A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
 -
HBC 200 115/230 1 200 125 16A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
Rugged, cost-optimized Industrial
MIW 202 universal 2 200 12 11A F1W: 160 x 51 x 198 mm
6.3" x 2" x 7.8"
-
HBC 300 115/230 1 300 125 25A F3: 132 x 62 x 300 mm
5.2" x 2.4" x 11.8"
Rugged, cost-optimized Industrial
HBC 65 115/230 1 300 125 25A F3: 132 x 62 x 300 mm
5.2" x 2.4" x 11.8"
Conduction/convection cooled
HBC 265 115/230 2 300 120,120 15,15A F3: 132 x 62 x 300 mm
5.2" x 2.4" x 11.8"
 -
HBC 465 115/230 4 300 24,+/-24,-24 20,+/-3,-1 F3: 132 x 62 x 300 mm
5.2" x 2.4" x 11.8"
 -
MIW 302 universal 2 300 125 15A F3: 132 x 62 x 300 mm
5.2" x 2.4" x 11.8"
Both outputs highly regulated and individually adjustable
HBC 65F 115/230 1 500 125 40A FF3: 152.9 x 61 x 295 mm
6.02" x 2.4" x 11.62
Forced air
HBC 319 115/230 1 500 125 20A F4:130 x 62 x 353 mm
5.1" x 2.43" x 13.9
Convection/conduction cooled
LVC 319 115/230 1 500 20 40A F4:130 x 62 x 353 mm
5.1" x 2.43" x 13.9
-
HBL 600 115/230 1 600 125 25 F6: 210 x 38 x 351 mm;

(8.3" x 1.5" x 13.8"

Open construction with base plate and isolating cover
HBC 319F 115/230 1 700 125 29A FF4: 155 x 62 x 356 mm
6.1"x 2.43"x 14"
Forced air
HBL 800-1U 230 1 800 150 - 1U (1.75”) x 19” x 11” Low profile, rack-mount chassis
HBL 1K 115/230 1 1000 56 38A F6: 210 x 66 x 351 mm
8.3" x 2.6" x 13.8"
Rugged, Industrial conduction/convecgtion cooled
HBC 1K 115/230 1 1000 60 75A U5512:127 x 127 x 313.7 mm
5" x 5" x 12.35"
Forced air
2HBC 265 115/230 4 1000 - - 279.4 x 63.5 x 292.1 mm
11" X 2.5" x 11.5"
-
HBC 1K2 115/230 1 1200 60 50A U5512: 127 x 127 x 315 mm
5" x 5" x 12.52"
Forced air
HBL 1K5F 230 1 1500 125 62A FF6: 236 x 65 x 349 mm
9.28" x 2.55" x 13.75"
Forced air
HBL 1K6-1U 230 1 1600 150 - 1U (1.75") x 19" x 11" Low profile, rack-mount chassis
MOT 2000 170...265 1 2000 54 70A 188 x 124.5 x 292.1 mm
7.4" x 4.9" x 11.5"
Forced air
HBL 2KF 230 1 2000 125 83A FF6: 236 x 65 x 349 mm
9.28" x 2.55" x 13.75"
Forced air
HBC 5KC 240Vac or
250Vdc
1 5000 250 200A Z51118:
291 x 57.2 x 457.2 mm
11.5" x 5.25" x 18"
Compact chassis
HBC 5K 180...264 1 5000 300 25A 4U x 19" x 15"
177 x 482.6 x 482.6 mm
6.97" x 19" x 19"
19" rack mount
Note: Most models can be equipped with auto-ranging or switch selection 115/230 as an option.
Return to top
Encapsulated PFC-Input (Power Factor Corrected) Power Supplies
for immuity to shock, vibration, moisture, humidity, dust and insects.
PPF 300 universal 1 300 72 25A P300:112.5 x 53.3 x 201.4 mm
4.43" x 2.10" x 7.93"
Encapsulated for harsh-environments
PPF 65 universal 1 500 72 30A P 65: 154.9 x 67.6 x 279.4 mm
6.1" x 2.66" x 11"
Encapsulated for harsh-environments
Return to top
PFC (Power Factor Corrected) Power Supplies
PFC 67 universal 3 100 24,+/-24 10,+/-3A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
 -
PFC 90 universal 1 150 60 20A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
 -
PFC 53 universal 1 200 120 25A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
 -
PFC 200 universal 1 200 125 16A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
Conduction/convection cooled
PFC 65 universal 1 300 125 25A F3: 132 x 62 x 300 mm
5.2" x 2.4" x 11.8"
-
PFC 319 universal 1 450 60 20A F4:130 x 62 x 353 mm
5.1" x 2.43" x 13.9
-
PFC 65F universal 1 500 48 40A FF3: 152.9 x 61 x 295 mm
6.02" x 2.4" x 11.62
Forced air
PFC 700 universal 1 700 13.2 60A 208.3 x 55.9 x 254 mm
8.2" x 2.2" x 10"
Low profile
PFC 319F universal 1 750 125 31A FF4: 155 x 62 x 356 mm
6.1"x 2.43"x 14"
Forced air
PFL 800F-1U universal 1 800 48 34A 44.5 x 482.6 x 508 mm
1U (1.75") x19" x 20"
1.75" x 19" x 20"
Low profile
PFC 419F universal 1 1000 48 60A FFX: 185 x 66 x 351 mm
7.3"x 2.6" x 13.8"
Forced air
PFC 1000 universal 1 1000 120 40/75A U5512: 127 x 127 x 313.7 mm
5" x 5" x 12.35"
Forced air
PFC 1500 universal 1 1500 125 120A U5512: 127 x 127 x 313.7 mm
5" x 5" x 12.35"
Forced air
PFL 1500F universal 1 1500 125 62A F20:279 x 64 x 292 mm
11" x 2.5" x 11.5"
Low profile,
Forced air
PFC 4500 universal 1 4500 48 31A 3U" x 19" x 18"
132.6 x 482.6 x 457.2 mm
5.22" x 19" x 18"
High power
Return to top
Battery Chargers/UPS
BCH 100 95-264ac
or
120-360dc
1 100 55.2 8A F1: 112 x 51 x 201 mm
4.43" x 2" x 7.9"
LBD, Alarms
BCH 150
formerly BCH 1663
95-264ac
or
120-360dc
1 150 24 86A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
LBD, Alarms
BCH 151 95-264ac
or
120-360dc
1 150 55.2 10.86A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
LBD, BTC, Charger Fail Alarm, LBA
BCH 151 & BCP 151 (PFC-input) 95-264ac
or
120-360dc
1 150 55.2 10A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
LBD, BTC (option), C-Fail Alarm, LBA
PFC&non-PFC-Input
BCM 150 95-264ac
or
120-360dc
1 150 55.2 10.86A F2: 112.5 x 57.2 x 274.3 mm
4.43" x 2.25" x 10.8"
A-Meter,
Alarms (optional)
BCH 300 115/230 1 300 125 - F3: 132 x 62 x 300 mm
5.2" x 2.4" x 11.8"
Charger Fail Alarm
BCH 301 & BCP 301 (PFC-input) 115/230

90-264 PFC
1 300 125 18A F4:130 x 62 x 353 mm
5.1" x 2.43" x 13.9
LBD, BTC (option), C-Fail Alarm, LBA
PFC&non-PFC-Input
BCH 300 - 500T 115/230
or 250Vdc
1 300-500 400 - 429 x 244 x 341 mm
16.93" x 9.61" x 13.42"
Transportable. Heavy ruggedizing, conformal coating, waterproof case
BCH MO1 115/230 1 300-750 138 - 4U (6.97")x19"x7" Configurable charger system
BCH 65-3U/19M 115/230 1 300 138 21A 3U x 19" x 3" Output fail alarm, front panel adjustment, output voltage & current meters, input switch
BCH 500 115/230 1 500 24,48 18A F4:130 x 62 x 353 mm
5.1" x 2.43" x 13.9
Charger fail alarm
BCH 501 115/230

95-264 PFC
1 500 138 36A F4 + F1 'piggy-backed':
130 x 152 x 353 mm
5.1” x 6" x 13.8"
LBD, BTC, Form C-Fail Alarm, LBA
PFC&non-PFC-Input
BCH 1500-AEQ 95-264ac 1 1500 144 10A 3U3: 187 x 132 x 432 mm
7.4" x 5.2" x 17"
Automatic auto-equalize function
Abbreviations: LBD: Low Battery Disconnect; BTC: Battery Temperature Compensation; LBA: Low Battery Alarm
Return to top
PFC-Input Battery Chargers/UPS
BCP 151 90-264 PFC 1 150 48 10 F2L: 114 x 57 x 310 mm
4.5"x 2.3" x 12.2"
LBD, BTC (option), C-Fail Alarm, LBA
BCP 301 90-264 PFC 1 300 125 22 F4:130 x 62 x 353 mm
5.1" x 2.43" x 13.9
LBD, BTC (option), C-Fail Alarm, LBA
BCP 501 90-264 PFC 1 500 125 18 F5: 130 x 64 x 432 mm
5.1" x 2.5" x 17"
LBD, BTC (option), C-Fail Alarm, LBA
Return to top
DC- Output Mini-UPS Systems (stand-alone)
UPS 12-7AH 95 ... 264 1 50 13.6 3 157.5 x 71.1 x 254 mm
6.2" x 2.8" x 10"
Built-in 7AH battery. Compact design.
UPS 12-14AH 95 ... 264 1 150 13.8 10 139.7 x 177.8 x 254 mm
5.5" x 7"x 10"
Built-in 14AH battery. Compact.
Return to top
Medical Power Supplies (UL 601.1)
HOW 100 95 - 264 1 100 130 20 F0: 86.4 x 48.3 x 154.9 mm
3.4" x 1.9" x 6.10"
-
MPS 420 115/230 4 150 12 20 140 x 86 x 151 mm(5.5" x 3.4" x 5.95") Autoranging
MPS 520 115/230 6 180 12 20 140 x 86 x 151 mm(5.5" x 3.4" x 5.95") Autoranging
Return to top
AC - Fail Alarm Circuit
ACF 2624 115/230 1 - - - 67.8 x 55.9 x 35.8 mm
2.67" x 2.2" x 1.41"
1-2ms detection time
Return to top
Copyright ©2005 Absopulse Electronics Ltd. All Rights Reserved

Note: Universal input is 90V … 264VAC in continuous range.

ac/dc power supplies, ac/dc power supplies, ac/dc converters, ac/dc converters, battery chargers, battery chargers, power factor corrected, power factor corrected, power factor correction, power factor correction, power factor corrected, power factor correction, ac/dc power supplies, ac/dc power supplies, ac/dc converters, ac/dc converters, battery chargers, battery chargers, power factor correctipn, power factor correction, power factor correction,